Honeywell S89F1098/U Direct Spark Ignition Control, 24 VAC, 2 A, Liquid Propane, Natural Gas Gas, Import

S89F1098 MFG #: S89F1098/U
Requires Quote
Honeywell Spark Ignition Control, Direct, 24 VAC, 2 A, Liquid Propane, Natural Gas Gas, 30 s Prepurge, 4 s Lockout, 5-1/4 in Height, 4-1/16 in Width, 1-15/16 in Depth, Domestic/Import: Import
QTY
  • Control ignition sequence and gas control operation
  • Generate high voltage potential for main burner ignition
  • Lockout after one trial for ignition if main burner fails to ignite
  • Reset from thermostat after lockout
  • 2 sec at 2.5 mA flame failure response time
  • 60 Hz frequency
  • -40 to 175 deg F ambient temperature
  • Single trial for main burner ignition sequence
  • VR8205, VR8305 gas control
  • Two-rod flame sense
  • External (120 VAC powered) high voltage spark generator
  • 1 ignition trials to lockout
  • 0.8 sec max flame failure re-ignition time
  • Use modules (except S87C) with any combination gas control designed for direct spark applications an
Control ignition sequence and gas control operation
Generate high voltage potential for main burner ignition
Lockout after one trial for ignition if main burner fails to ignite
Reset from thermostat after lockout
2 sec at 2.5 mA flame failure response time
60 Hz frequency
-40 to 175 deg F ambient temperature
Single trial for main burner ignition sequence
VR8205, VR8305 gas control
Two-rod flame sense
External (120 VAC powered) high voltage spark generator
1 ignition trials to lockout
0.8 sec max flame failure re-ignition time
Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less