Square D™ TeSys™ D LC1D093BL LC1D IEC Contactor With Protective Cover, 24 VDC V Coil, 9 A, 3NO Contact, 3 Poles
LC1D093BL
MFG #: LC1D093BL
$170.01
/ EA
Estimated Delivery 7 to 10 Business Days
- Manufacturer: Schneider Electric
- Series: LC1D
- Coil Voltage: 24
- Maximum Load Current: 9
- Coil Power Rating: 7.5
- Number of Poles: 3
- Frequency Rating: 50/60
- Wattage: 1.56/0.2
- Contact Configuration: 3NO
- Number of Auxiliary Contacts: 1NO-1NC
- Contact Rating: 9 A at 440 VAC
- Terminal Type: Spring
- Enclosure Type: Open
- Operating Cycles: 30
- Operating Temperature: -4 to 140
- Mounting Type: Plate/Rail
- Dimensions: 3.15 in H x 1.77 in W x 3.74 in D
- Brand: Square D™
Square D™ TeSys™ D IEC Contactor, Series: LC1D, 24 VDC Coil, 9 A Maximum Load Current, 7.5 hp Coil, 3 Pole, 50/60 Hz Frequency, 1.56/0.2 W Wattage, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 9 A at 440 VAC Contact, Spring Terminal, Open Enclosure, 30000000 Cycles Operating Cycles, -4 to 140 deg F Operating, Plate/Rail Mounting, 3.15 in H x 1.77 in W x 3.74 in D Dimensions
- 6 kV conforming to IEC 60947 rated impulse withstand voltage
- III overvoltage category
- 16 A at <=140 deg F (60 deg C) power circuit/10 A at <=140 deg F (60 deg C) signaling circuit conven
- 250 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60
- 20 A gG at <=690 V coordination type 2 power circuit/25 A gG at <=690 V coordination type 1 power ci
- 2.5 mOhm at 50 Hz - Ith 25 A power circuit average impedance
- 65.45 to 88.55 ms closing/20 to 30 ms opening operating time
- 3600 cycles/hr at <=140 deg F (60 deg C) operating rate
- Built-in bidirectional peak limiting diode suppressor coil technology
- 40 ms time constant
- 2.4 W at 68 deg F (20 deg C) inrush power
- 25 to 400 Hz signaling circuit frequency
- 5 mA signaling circuit minimum switching current
- 17 V signaling circuit minimum switching voltage
- 1.5 ms on energisation between NC and NO contacts/1.5 ms on de-energisation between NC and NO contac
- >10 MOhm signaling circuit insulation resistance
- TH protective treatment
- 3 pollution deg
6 kV conforming to IEC 60947 rated impulse withstand voltage
III overvoltage category
16 A at <=140 deg F (60 deg C) power circuit/10 A at <=140 deg F (60 deg C) signaling circuit conventional free air thermal current
250 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5-1/250 A DC signaling circuit conforming to IEC 60947-5-1 irms rated making capacity
20 A gG at <=690 V coordination type 2 power circuit/25 A gG at <=690 V coordination type 1 power circuit/10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
2.5 mOhm at 50 Hz - Ith 25 A power circuit average impedance
65.45 to 88.55 ms closing/20 to 30 ms opening operating time
3600 cycles/hr at <=140 deg F (60 deg C) operating rate
Built-in bidirectional peak limiting diode suppressor coil technology
40 ms time constant
2.4 W at 68 deg F (20 deg C) inrush power
25 to 400 Hz signaling circuit frequency
5 mA signaling circuit minimum switching current
17 V signaling circuit minimum switching voltage
1.5 ms on energisation between NC and NO contacts/1.5 ms on de-energisation between NC and NO contacts non-overlap time
>10 MOhm signaling circuit insulation resistance
TH protective treatment
3 pollution deg