Crouse-Hinds Arktite® EPC46042 WT50 3 Dust Ignitionproof Grounding Style 2 Interlocked Raintight Explosionproof Receptacle With Spring Door Housing, 50 A Cutler-Hammer Breaker, 480 VAC, 250 VDC, 60 A, 4 Poles, 3 Wires, Natural

EPC46042 WT50 3 MFG #: EPC46042 WT50 3
$19,274.23 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Interlocked Style 2
  • Series: EPC
  • Voltage Rating: 600
  • Amperage Rating: 60
  • Number of Poles: 4
  • Number of Wires: 3
  • NEMA Rating: NEMA 3/12/7C/7D/9F/9G
  • Material: Copper Free Aluminum
  • Dimensions: 24-1/2 in H x 12-13/16 in W x 14-3/8 in D
  • Brand: Crouse-Hinds
Crouse-Hinds Arktite® Explosionproof Receptacle, Dust Ignitionproof Grounding Style 2 Interlocked Raintight, Series: EPC, 480 VAC, 250 VDC, 60 A, 4 Poles, 3 Wires, NEMA 3/7C/7D/9F/9G/12, Copper Free Aluminum, Natural, 10-5/8 in L x 14-3/8 in W x 24-1/2 in H
  • Mechanical interlock mechanism for dead front construction
  • Mechanical interlock mechanism for dead front construction
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • A spring door receptacle, located at bottom of 30 A, 60 A and 100 A units and at front of 200 A unit
  • Plug and receptacle contacts cannot be made or broken under load
  • Plug and receptacle contacts cannot be made or broken under load
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • Operating handles can be padlocked in either "on" or "off" positions
  • Operating handles can be padlocked in either ON or OFF positions
  • Quick installation and leveling is provided by the 3-point mounting arrangement which has one keyhol
  • Breakers are trip free of the handles and will open under short circuit or overload even if the hand
  • Quick installation and leveling is provided by the 3-points mounting arrangement which has one keyho
  • Bodies have four taper tapped conduit hubs with integral bushings, two are located at top and two di
Mechanical interlock mechanism for dead front construction
Mechanical interlock mechanism for dead front construction
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
A spring door receptacle, located at bottom of 30 A, 60 A and 100 A units and at front of 200 A units, is mechanically interlocked with the circuit breaker operating mechanism for maximum safety
Plug and receptacle contacts cannot be made or broken under load
Plug and receptacle contacts cannot be made or broken under load
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
Operating handles can be padlocked in either "on" or "off" positions
Operating handles can be padlocked in either ON or OFF positions
Quick installation and leveling is provided by the 3-point mounting arrangement which has one keyhole slot at top and two open slots at bottom
Breakers are trip free of the handles and will open under short circuit or overload even if the handle is locked in the ON position
Quick installation and leveling is provided by the 3-points mounting arrangement which has one keyhole slot at top and two open slots at bottom
Bodies have four taper tapped conduit hubs with integral bushings, two are located at top and two directly below