Klein® CL2500 Non-Contact Clamp Meter, 750 VAC, 1000 VDC, 1000 A AC/DC, 60 MOhm, 45 to 400 Hz, 1.97 in Jaw, LCD Display

CL2500 MFG #: CL2500
Requires Quote
Klein® Clamp Meter, Non-Contact, 750 VAC, 1000 VDC, 1000 A AC/DC Electrical Rating, 60 MOhm Resistance, 45 to 400 Hz Frequency, 1.97 in Jaw, 6000 Count, LCD Display, +/-1.5% + 8 Digits AC Current Accuracy, +/-2% + 5 Digits AC, +/-0.8% + 10 Digits DC Voltage Accuracy, Safety Rating: CAT III 1000 VAC, CAT IV 600 VAC, (2) AAA Batteries Power Source, 32 to 104 deg F Operating, 8.09 in H x 2.56 in W x 1.38 in D Dimensions
QTY
  • Extra wide jaw opening accommodates a greater measuring area
  • True rms accurate readings for all signals
  • Measures capacitance, great for H VAC work
  • Magnetic mount on back secures meter and frees hands
  • Line splitter, Tradesman Pro carrying cases - small, medium, large
  • 2 deg pollution, 3.3 ft drop protection, IP42, 6000 uF capacitance test
  • AC current range - 600 uA with accuracy of +/-(2% + 5 digits), 0.1 uA resolution, 2000 uA with accur
  • Resistance range - 600 Ohm - 6 MOhm with accuracy of +/-(1% + 4 digits), 0.1 Ohm - 0.001 MOhm resolu
  • AC voltage range - 600 mV - 750 V with accuracy of +/-(2% + 5 digits), 0.1 mV - 1 V resolution, 750
  • DC voltage range - 600 mV - 600 V with accuracy of +/-(0.5% + 4 digits), 0.1 mV - 0.1 V resolution,
  • Capacitance range - 60 nF - 6000 uF with accuracy of +/-(3.5% + 6 digits), 0.01 nF - 1 uF resolution
Extra wide jaw opening accommodates a greater measuring area
True rms accurate readings for all signals
Measures capacitance, great for H VAC work
Magnetic mount on back secures meter and frees hands
Line splitter, Tradesman Pro carrying cases - small, medium, large
2 deg pollution, 3.3 ft drop protection, IP42, 6000 uF capacitance test
AC current range - 600 uA with accuracy of +/-(2% + 5 digits), 0.1 uA resolution, 2000 uA with accuracy +/-(1.5% + 5 digits), 1 uA resolution, 60 A with accuracy of +/-(2.9% + 15 digits), 0.01 A resolution, 600 A - 1000A with accuracy of +/-(1.9% + 8 digi
Resistance range - 600 Ohm - 6 MOhm with accuracy of +/-(1% + 4 digits), 0.1 Ohm - 0.001 MOhm resolution, 60 MOhm with accuracy of +/-(2% + 4 digits), 0.001 MOhm resolution, 600 V rms overload protection
AC voltage range - 600 mV - 750 V with accuracy of +/-(2% + 5 digits), 0.1 mV - 1 V resolution, 750 V RMS overload protection
DC voltage range - 600 mV - 600 V with accuracy of +/-(0.5% + 4 digits), 0.1 mV - 0.1 V resolution, 1000 V with accuracy of +/-(0.8% + 10 digits), 1 V resolution, 1000 V rms overload protection
Capacitance range - 60 nF - 6000 uF with accuracy of +/-(3.5% + 6 digits), 0.01 nF - 1 uF resolution, 600 V RMS overload protection