Square D™ 9012GAW6 Electromechanical Pressure Switch, 5 to 250 psi Pressure, 10 to 49 psi Differential, 1NC-1NO Contact, NPT Conduit/Screw Clamp Connection, 6 A at 120 VAC/0.27 A at 250 VDC Contact

9012GAW6 MFG #: 9012GAW6
Requires Quote
Square D™ Pressure Switch, Electromechanical, Series: 9012G, 5 to 250 psi Pressure, 10 to 49 psi Differential, 750 psi Maximum, 1NC-1NO Contact Configuration, 6 A at 120 VAC/0.27 A at 250 VDC Contact, 120 cpm Operating Cycles, -10 to 185 deg F, NPT Conduit/Screw Clamp Connection, Nitrile Diaphragm, Aluminum Housing Material, NEMA 4/4X/13 Enclosure, 3.5 in W x 2.63 in D x 5.55 in H Dimensions
QTY
  • High shock-resistance
  • High set-point stability
  • Internal or external range adjustment
  • No drain line required
  • Dual numerical range scale (psi and kPa)
  • Nitrile diaphragms and zinc-plated steel flanges are standard
  • Diaphragms of FKM fluorocarbon or ethylene propylene are available as well as stainless steel flange
  • NC-NO, SPDT-DB, Form Z, snap action, silver nickel contacts
  • Hydraulic oil (-40 to 250 deg F), non-corrosive liquids, air, non-corrosive gas controlled fluid
  • 1/4 in 18 NPTF conforming to UL 508 fluid connection
  • Regulation between 2 thresholds, adjustable scale
  • 4 screw terminal block
  • Screw clamp terminals, 22 to 12 AWG electrical connection
  • Zinc plated steel flange
  • Nitrile (Buna-N) diaphragm
  • Panel mounting
  • Die cast aluminum alloy 380, 120 operating cycles/min (maximum)
  • 1/2 in NPT conduit entrance cable entry
  • Water, dust, oil and corrosion-resistant (indoor/outdoor) environmental conditions
High shock-resistance
High set-point stability
Internal or external range adjustment
No drain line required
Dual numerical range scale (psi and kPa)
Nitrile diaphragms and zinc-plated steel flanges are standard
Diaphragms of FKM fluorocarbon or ethylene propylene are available as well as stainless steel flanges
NC-NO, SPDT-DB, Form Z, snap action, silver nickel contacts
Hydraulic oil (-40 to 250 deg F), non-corrosive liquids, air, non-corrosive gas controlled fluid
1/4 in 18 NPTF conforming to UL 508 fluid connection
Regulation between 2 thresholds, adjustable scale
4 screw terminal block
Screw clamp terminals, 22 to 12 AWG electrical connection
Zinc plated steel flange
Nitrile (Buna-N) diaphragm
Panel mounting
Die cast aluminum alloy 380, 120 operating cycles/min (maximum)
1/2 in NPT conduit entrance cable entry
Water, dust, oil and corrosion-resistant (indoor/outdoor) environmental conditions