Square D™ Contactor, 3-Phase Type S Non-Reversing, Series: 8502, 110/120 VAC Coil, 40 hp at 200 VAC, 50 hp at 230 VAC, 100 hp at 460/575 VAC Coil, 3 Pole, 50/60 Hz Frequency, 30 kW at 200 V/37 kW at 230 V/37 kW at 460/575 V Wattage, 135 A Contact, Box Lug Connection, Screw Clamp Terminal, NEMA 1 Enclosure, 3 cpm Operating Cycles, 0 to 40 deg C Operating, Sheet Steel, Painted, 25.16 in H x 11.26 in W x 9.02 in D Dimensions
QTY
  • A normally open holding circuit contact for 3-wire control is provided as standard
  • For flexibility field installable or factory modified accessories include auxiliary contacts, power
  • Bell crank design promotes superior electrical and mechanical life
  • NEMA sizes 00 to 5 are supplied with coils that are designed to operate satisfactorily on line volta
  • NEMA sizes 5, 6 and 7 contactors are supplied with a DC coil operated by a solid state rectifier cir
  • Sizes 00 to 2 contactors use a class 9999 SX11 auxiliary contact as the holding circuit contact
  • Sizes 3 to 7 contactors use a class 9999 SX6 auxiliary contact as the holding circuit contact
  • NEMA type 1 general purpose enclosure
  • Used to switch heating loads capacitors, transformers and electric motors where overload protections
  • 600 VAC system voltage
  • Screw clamp terminal connection type
  • Without indicator
  • 40 hp at 200 VAC, 50 hp at 230 VAC, 100 hp at 460 VAC, 100 hp at 575 VAC, separate control circuit
A normally open holding circuit contact for 3-wire control is provided as standard
For flexibility field installable or factory modified accessories include auxiliary contacts, power poles and cover mounted control stations
Bell crank design promotes superior electrical and mechanical life
NEMA sizes 00 to 5 are supplied with coils that are designed to operate satisfactorily on line voltages of 85% to 110% of rated voltage
NEMA sizes 5, 6 and 7 contactors are supplied with a DC coil operated by a solid state rectifier circuit that is powered by an AC source
Sizes 00 to 2 contactors use a class 9999 SX11 auxiliary contact as the holding circuit contact
Sizes 3 to 7 contactors use a class 9999 SX6 auxiliary contact as the holding circuit contact
NEMA type 1 general purpose enclosure
Used to switch heating loads capacitors, transformers and electric motors where overload protections is provided separately
600 VAC system voltage
Screw clamp terminal connection type
Without indicator
40 hp at 200 VAC, 50 hp at 230 VAC, 100 hp at 460 VAC, 100 hp at 575 VAC, separate control circuit