Eaton Wiring Devices

Eaton Wiring Devices Arrow Hart TRSGF15W TRSGF Duplex Tamper-Resistant GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, White

TRSGF15W MFG #: TRSGF15W
$39.91 / EA
Low Stock
  • Amperage Rating: 15 A
  • Color: White
  • Country of Origin: CN
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Enclosure: IP65
  • Frequency Rating: 60 Hz
  • Manufacturer Name: Eaton
  • Material: Thermoplastic
  • NEMA Rating: NEMA 5-15R
  • Number of Poles: 2
  • Number of Wires: 3
  • Series: TRSGF
  • Temperature Rating: -35 to 66 deg C
  • Terminal Type: Back/Side Wire
  • Type: Duplex Tamper-Resistant
  • Voltage Rating: 125 VAC
GFCI receptacles are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, break rooms and food service areas, the NEC requires GFCI receptacles. Arrow Hart Self-Test GFCI receptacles are UL Listed and fully compliant with all of the latest UL943 Class A GFCI and UL498 requirements. The Self-Test GFCIs conduct an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage.
QTY
  • Application
  • Standards
  • Includes
  • Item Features
Commercial, Industrial and Institutional
cULus Listed to UL 498|UL 943|E60120|2011 NEC Article 406.11 Compliant|CSA Certified|NOM Certified
Matching Thermoplastic Wallplate
  • If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or end of life condition
  • Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
  • Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
  • Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts materials
  • Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
  • Withstands 2000 V per UL498 dielectric voltage
  • V2 rated UL94 flammability
  • Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
  • #14 to 10 AWG terminal accommodation, Back Wire and Side Wire