FLIR® CM82 CM Series Industrial Grade Power Clamp Meter, 600 A, 99.9 VAC/VDC, 99.99 kOhm, 20 Hz to 9.999 kHz, 1.45 in Jaw, LCD Display

CM82 MFG #: CM82
Requires Quote
FLIR® Power Clamp Meter, Industrial Grade, Series: CM Series, 600 A, 99.9 VAC/VDC Electrical Rating, 99.99 kOhm Resistance, 20 Hz to 9.999 kHz Frequency, 1.45 in Jaw, 10000 Count, LCD Display, True RMS AC Response, +/-2 % AC Current Accuracy, +/-3% Power Accuracy, +/-1 or 0.7 % Voltage Accuracy, Frequency Counter: +/-0.5%, Safety Rating: CAT IV 600 VAC/CAT III 1000 VAC, Battery Power Source, 32 to 50 deg F Operating, 10.3 in L x 3.9 in W x 1.9 in H Dimensions, ABS/Polycarbonate/Thermoplastic Elastomer, Black/Gray
QTY
  • VFD mode accurately analyzes non-sinusoidal waveforms and noisy signals in VFD controlled equipment
  • Harmonics mode locates noise from different electrical draws to realign harmonics and reduce electro
  • Phase rotation analyzes 3-phase systems to measure power draw and verify if power is evenly balanced
  • Inrush current measures hard and soft start-up inrush current spikes while equipment is ramping up
  • Power factor and active power monitors power quality improvements, such as start-up realignments on
  • Bright, dual LED work lights make your work safer/easier in poorly lit locations especially useful w
  • Rugged and shock-resistant double molded case design and extra thick rubber on the corners absorbs s
  • 3.999 mF capacitance
  • 600 A AC maximum, 100 ms integration time inrush current
  • 30 Ohm continuity threshold
  • 1st to 25th order harmonics
  • 10 to 60 kW power rating
VFD mode accurately analyzes non-sinusoidal waveforms and noisy signals in VFD controlled equipment and enables accurate voltage and frequency measurements for maintenance and troubleshooting tasks
Harmonics mode locates noise from different electrical draws to realign harmonics and reduce electro-mechanical equipment stress
Phase rotation analyzes 3-phase systems to measure power draw and verify if power is evenly balanced
Inrush current measures hard and soft start-up inrush current spikes while equipment is ramping up
Power factor and active power monitors power quality improvements, such as start-up realignments on 3-phase equipment
Bright, dual LED work lights make your work safer/easier in poorly lit locations especially useful when the lights are out or obstacles block your inspection targets
Rugged and shock-resistant double molded case design and extra thick rubber on the corners absorbs shock to enhance jobsite reliability and long haul durability
3.999 mF capacitance
600 A AC maximum, 100 ms integration time inrush current
30 Ohm continuity threshold
1st to 25th order harmonics
10 to 60 kW power rating