Crouse-Hinds Arktite® EBBRA604 Dust-Ignitionproof Grounding Style 2 Explosionproof Raintight Interlocked Receptacle, 480 VAC, 50 A, 3 Poles, 3 Wires, Natural

EBBRA604 MFG #: EBBRA604
$9,906.60 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Dust Ignition Proof
  • Series: EBBR
  • Voltage Rating: 480
  • Amperage Rating: 50
  • Number of Poles: 3
  • Number of Wires: 3
  • NEMA Rating: NEMA 3/3R/12/7BCD/9FG
  • Material: Aluminum
  • Dimensions: 24.7 in L x 14.06 W x 10.25 in D
  • Brand: Crouse-Hinds
Crouse-Hinds Arktite® Interlocked Receptacle, Dust-Ignitionproof Grounding Style 2 Explosionproof Raintight, Series: EBBR, 480 VAC, 50 A, 3 Pole, 3 Wires, NEMA 3/3R/12/7BCD/9FG NEMA Rating, Copper-Free Aluminum, Natural, 24.7 in L x 14.06 W x 10.25 in D Dimensions
  • Rugged, corrosion-resistant, cast copper-free aluminum construction
  • Rugged, corrosion-resistant, cast copper-free aluminum construction
  • Accepts compatible Arktite plug of same rating and configuration
  • Mechanical interlock mechanism for dead front construction
  • Mechanical interlock mechanism for dead front construction
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • A spring door receptacle, located at the bottom of the unit, is mechanically interlocked with the ci
  • Plug and receptacle contacts cannot be made or broken under load
  • Plug and receptacle contacts cannot be made or broken under load
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • Operating handles can be padlocked in either ON or OFF positions
  • Operating handles can be padlocked in either ON or OFF positions
  • Breakers are trip-free of the handles and will open under short circuit or overload even if the hand
  • Component operating handles located through the right side wall of the body permits visual confirmat
  • Semi-clamshell enclosure design, with an external machined flat joint flame path between body and co
  • Semi-clamshell enclosure design, with an external machined flat joint flame path between body and co
  • Minimum enclosure-to-enclosure spacing with little interference between the opened cover and an adja
  • Minimum enclosure to enclosure spacing with little interference between the opened cover and an adja
  • Copper-free aluminum hinges allow the cover to swing well out of the way
  • Stainless steel, quick release, captive, hex head cover bolts
  • Stainless steel, quick release, captive, hex head cover bolts
  • Stainless steel springs provide clear indication cover bolts are fully retracted from body
  • Stainless steel springs provide clear indication cover bolts are fully retracted from body
  • Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufactu
  • Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufactu
  • Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure
  • Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure
  • Neoprene cover gasket permanently attached to the cover seals out moisture
  • Neoprene cover gasket permanently attached to the cover seals out moisture
  • Tap-on mounting feet
  • Tap-on mounting feet
  • Without circuit breaker
Rugged, corrosion-resistant, cast copper-free aluminum construction
Rugged, corrosion-resistant, cast copper-free aluminum construction
Accepts compatible Arktite plug of same rating and configuration
Mechanical interlock mechanism for dead front construction
Mechanical interlock mechanism for dead front construction
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
A spring door receptacle, located at the bottom of the unit, is mechanically interlocked with the circuit breaker operating mechanism for safe and dependable operation
Plug and receptacle contacts cannot be made or broken under load
Plug and receptacle contacts cannot be made or broken under load
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is de-energized
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is de-energized
Operating handles can be padlocked in either ON or OFF positions
Operating handles can be padlocked in either ON or OFF positions
Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ON position
Component operating handles located through the right side wall of the body permits visual confirmation of correct component assembly and operation
Semi-clamshell enclosure design, with an external machined flat joint flame path between body and cover makes interior components easily accessible
Semi-clamshell enclosure design, with an external machined flat joint flame path between body and cover makes interior components easily accessible
Minimum enclosure-to-enclosure spacing with little interference between the opened cover and an adjacent enclosure
Minimum enclosure to enclosure spacing with little interference between the opened cover and an adjacent enclosure
Copper-free aluminum hinges allow the cover to swing well out of the way
Stainless steel, quick release, captive, hex head cover bolts
Stainless steel, quick release, captive, hex head cover bolts
Stainless steel springs provide clear indication cover bolts are fully retracted from body
Stainless steel springs provide clear indication cover bolts are fully retracted from body
Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufacturer's breakers
Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufacturer's breakers
Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure
Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure
Neoprene cover gasket permanently attached to the cover seals out moisture
Neoprene cover gasket permanently attached to the cover seals out moisture
Tap-on mounting feet
Tap-on mounting feet
Without circuit breaker