Eaton Wiring Devices TWRSGF20V TWRSGF Tamper/Weather-Resistant Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, Ivory

TWRSGF20V MFG #: TWRSGF20V
$79.88 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Tamper/Weather-Resistant
  • Series: TWRSGF
  • Voltage Rating: 125
  • Amperage Rating: 20
  • Frequency Rating: 60
  • Number of Poles: 2
  • Number of Wires: 3
  • NEMA Rating: NEMA 5-20R
  • Grade: Specification
  • Temperature Rating: -35 to 66
  • Terminal Type: Back/Side Wired
  • Material: Polypropylene
  • Color: Ivory
  • Dimensions: 4.2 in H x 1.68 in W x 1.27 in D
  • Brand: Eaton Wiring Devices
Eaton Wiring Devices Duplex GFCI Receptacle, Tamper/Weather-Resistant, Series: TWRSGF, 125 VAC, 20 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-20R NEMA Rating, Specification Grade, -35 to 66 deg C, Back/Side Wire Terminal, Polypropylene, Ivory, 4.2 in H x 1.68 in W x 1.27 in D Dimensions
  • Meets and exceeds 10 kA short circuit testing and underwriters laboratories (UL) 2006 UL943 safety s
  • Performs periodic self tests to ensure integrity of GFCI protection if no ground fault protection is
  • Tapered backwire openings handle multiple wire sizes and types for applications up to 10 AWG solid o
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protect
  • Test and reset buttons are color matched to provide superior aesthetics
  • Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating fl
  • Exclusive built-in wire stripper provides fast stripping of wire without tools
  • Line-load miswiring protection GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Withstands 2000V per UL498 dielectric voltage
  • Full rated current current interrupting
  • Maximum 30 deg C after 100 cycles of overload at 150 percent of rated current (DC) temperature rise
  • 0.025 seconds (class A) trip time
  • 20 A maximum interrupting capacity
  • 14 to 10 AWG terminal accommodation
  • Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing
  • 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts
  • Brass/nickel-plated steel terminal screw, brass plated steel terminal clamps, ground screw green
Meets and exceeds 10 kA short circuit testing and underwriters laboratories (UL) 2006 UL943 safety standards
Performs periodic self tests to ensure integrity of GFCI protection if no ground fault protection is detected, the device will trip, will not reset and the status indicator light will glow amber
Tapered backwire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
Test and reset buttons are color matched to provide superior aesthetics
Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating floating installations
Exclusive built-in wire stripper provides fast stripping of wire without tools
Line-load miswiring protection GFCIs will not provide power downstream when wired incorrectly
Tri-combo head terminal and mounting screws
Withstands 2000V per UL498 dielectric voltage
Full rated current current interrupting
Maximum 30 deg C after 100 cycles of overload at 150 percent of rated current (DC) temperature rise
0.025 seconds (class A) trip time
20 A maximum interrupting capacity
14 to 10 AWG terminal accommodation
Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing
0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts
Brass/nickel-plated steel terminal screw, brass plated steel terminal clamps, ground screw green