Eaton Wiring Devices Arrow Hart SGF15A SGF15 Duplex GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, Almond

SGF15A MFG #: SGF15A
$31.29 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Series: SGF15
  • Voltage Rating: 125
  • Amperage Rating: 15
  • Frequency Rating: 60
  • Number of Poles: 2
  • Number of Wires: 3
  • NEMA Rating: NEMA 5-15R
  • Grade: Specification
  • Temperature Rating: -35 to 66
  • Terminal Type: Back/Side Wired
  • Material: Thermoplastic
  • Color: Almond
  • Dimensions: 4.2 in H x 1.68 in W x 1.27 in D
  • Brand: Eaton Wiring Devices
Eaton Wiring Devices Arrow Hart Duplex GFCI Receptacle, Series: SGF15, 125 VAC, 15 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-15R NEMA Rating, Specification Grade, -35 to 66 deg C, Back/Side Wire Terminal, Thermoplastic, Almond, 4.2 in H x 1.68 in W x 1.27 in D Dimensions
  • Performs periodic self tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Meets and exceeds 10 kA short circuit testing and underwriters laboratories (UL) UL943 safety standa
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides
  • Ground termination with backwire clamp provides secure wiring and reduces installation time
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered backwire openings handle multiple wire sizes and types for applications up to 10 AWG solid o
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protect
  • Line-load miswiring protection GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Tamper-resistant models comply with 2014 NEC Article 406.12
  • Weather resistant models comply with 2014 NEC Article 406.9 that states that all receptacles install
  • Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating fl
  • Withstands 2000 V per UL498 dielectric voltage
  • V0 per UL94 flammability, 0.025 seconds (Class A) trip time, No 14 to 10 AWG terminal accommodation
  • Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, z
  • #8 to 32 steel, brass plated, neutral screw nickel-plated, ground screw green terminal and ground sc
Performs periodic self tests to ensure integrity of GFCI protection
Visual trip indicator light gives quick notification of a tripped or "end of life" condition
Meets and exceeds 10 kA short circuit testing and underwriters laboratories (UL) UL943 safety standards
Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
Ground termination with backwire clamp provides secure wiring and reduces installation time
Tamper resistant shutters help prevent foreign objects from being inserted
Line side terminals are backed out and staked for fast installation
Horizontal test/reset button alignment provides larger unobstructed area
Test and reset buttons are color matched to provide superior aesthetics
Tapered backwire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
Line-load miswiring protection GFCIs will not provide power downstream when wired incorrectly
Tri-combo head terminal and mounting screws
Tamper-resistant models comply with 2014 NEC Article 406.12
Weather resistant models comply with 2014 NEC Article 406.9 that states that all receptacles installed in wet or damp locations must be weather resistant
Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating floating installations
Withstands 2000 V per UL498 dielectric voltage
V0 per UL94 flammability, 0.025 seconds (Class A) trip time, No 14 to 10 AWG terminal accommodation
Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts
#8 to 32 steel, brass plated, neutral screw nickel-plated, ground screw green terminal and ground screws, 0.07 in thick steel terminal clamps