EcoSystem® EC3DT4MWKU2S Dimming Studded Digital Ballasts, T4 CFL Lamp, 32 W Lamp, 120 VAC, Programmed/Rapid, 0.95 Ballast Factor

EC3DT4MWKU2S MFG #: EC3DT4MWKU2S
$188.70 / EA
Estimated Delivery 7 to 10 Business Days
EcoSystem® Digital Ballasts, Dimming Studded, T4 CFL Lamp, 32 W Lamp, 66 W Wattage, 120 VAC, 0.55 A, 50/60 Hz Frequency, Programmed/Rapid Start, 50 deg F Minimum Starting, Total Harmonic Distortion: <10%, Power Factor: 0.95, Yes Dimmable, 2 Lamps, Thermal Protection: Class P, 4-Pin Lamp Base, Ballast Factor: 0.95, NEMA 1 Enclosure, 167 deg F, Fixture Mounting, 4-9/10 in L x 3 in W x 1 in H Dimensions
  • Continuous, flicker free dimming from 100% to 5%
  • Compatible with EcoSystem® energy saver Node unit, GRAFIK Eye® QS with EcoSystem® unit, PowPak™ dimm
  • Supports standard 3-wire line-voltage phase control technology
  • Programmed rapid start design ensures full rated lamp life while dimming and cycling
  • Lamps turn on to any dimmed level without flashing to full brightness
  • Low harmonic distortion throughout the entire dimming range
  • Frequency of operation ensures that ballast does not interfere with infrared devices
  • Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay fail
  • Ultra-quiet operation
  • Protected from miswires of any input power to control lead, or from lamp leads to each other and/or
  • End-of-lamp-life protection circuitry ensures safe operation throughout entire lamp life
  • Nonvolatile memory restores all ballast settings after power failure
  • 100% compatible with all Lutron 3-wire fluorescent controls and EcoSystem® digital controls
  • 100% performance tested at factory
  • Ballast is grounded by the specified terminal or by a mounting screw to the fixture
  • Ballast mounts using two mounting tabs or studs within a fluorescent fixture
  • Within a fluorescent fixture mounting, K case size
  • 4560 lumens
  • 69.1 lm/W system efficacy
  • 1.44 ballast efficacy factor
Continuous, flicker free dimming from 100% to 5%
Compatible with EcoSystem® energy saver Node unit, GRAFIK Eye® QS with EcoSystem® unit, PowPak™ dimming module with EcoSystem® unit, and Quantum systems, allowing for integration into an existing/planned EcoSystem® lighting control system
Supports standard 3-wire line-voltage phase control technology
Programmed rapid start design ensures full rated lamp life while dimming and cycling
Lamps turn on to any dimmed level without flashing to full brightness
Low harmonic distortion throughout the entire dimming range
Frequency of operation ensures that ballast does not interfere with infrared devices
Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay failure
Ultra-quiet operation
Protected from miswires of any input power to control lead, or from lamp leads to each other and/or ground
End-of-lamp-life protection circuitry ensures safe operation throughout entire lamp life
Nonvolatile memory restores all ballast settings after power failure
100% compatible with all Lutron 3-wire fluorescent controls and EcoSystem® digital controls
100% performance tested at factory
Ballast is grounded by the specified terminal or by a mounting screw to the fixture
Ballast mounts using two mounting tabs or studs within a fluorescent fixture
Within a fluorescent fixture mounting, K case size
4560 lumens
69.1 lm/W system efficacy
1.44 ballast efficacy factor