ABB Soft Starter, Advanced Range, Series: PST, 208 to 690 VAC, 45 A, 50/60 Hz Frequency, 18.5/22/30 kW Motor, 100 to 250 VAC Coil, 1 to 30 s Start, 0 to 30 s Stop Timing, 3 ph, In-Line Screw Connection, Class 10 Overload Relay, 60 A Full Load, NEMA 1/4X/12/IP10/IP20/IP66 Enclosure, -13 to 140 deg F Operating, 196 mm L x 160 mm W x 260 mm H Dimensions
QTY
  • Both in-line and inside delta connection
  • Coated circuit boards available for reliable operation even in harsh environments
  • Full text display in 14 languages and 4-button keypad for easy set-up and operation
  • Built-in by-pass contactor on PSTB (from 370 A) for energy saving and easy installation
  • Prepared for external by-pass on PST (30 to 300 A)
  • Torque control for excellent control of pumps
  • Fieldbus communication using Profibus, Modbus, Devicenet or CANopen
  • Dual motor overload protection with classes 10A, 10, 20 and 30
  • Adaptable motor underload protection to detect pumps running dry
  • Adaptable locked rotor protection to detect jammed pumps
  • PTC protection to protect the motor from overheating
  • Adjustable kick start to start jammed pumps
  • Programmable output signal relays
  • Programmable pre-warning functions
  • Event log with time stamp
  • Analog output showing current, voltage, power factor 0 to 10 V, 0 to 20 mA, 4 to 20 mA
  • 18.5 kW at 400 V, 22 kW at 500 V, 30 kW at 690 V 3 ph motor power rating
Both in-line and inside delta connection
Coated circuit boards available for reliable operation even in harsh environments
Full text display in 14 languages and 4-button keypad for easy set-up and operation
Built-in by-pass contactor on PSTB (from 370 A) for energy saving and easy installation
Prepared for external by-pass on PST (30 to 300 A)
Torque control for excellent control of pumps
Fieldbus communication using Profibus, Modbus, Devicenet or CANopen
Dual motor overload protection with classes 10A, 10, 20 and 30
Adaptable motor underload protection to detect pumps running dry
Adaptable locked rotor protection to detect jammed pumps
PTC protection to protect the motor from overheating
Adjustable kick start to start jammed pumps
Programmable output signal relays
Programmable pre-warning functions
Event log with time stamp
Analog output showing current, voltage, power factor 0 to 10 V, 0 to 20 mA, 4 to 20 mA
18.5 kW at 400 V, 22 kW at 500 V, 30 kW at 690 V 3 ph motor power rating