Bussmann Low-Peak™ LP-CC-4-1/2 Current Limiting Time Delay Fuse, 4.5 A, 600 VAC/150 VDC, 20/200 kA Interrupt, CC Class, Cartridge Body

LP-CC-4-1/2 MFG #: LP-CC-4-1/2
Requires Quote
Bussmann Low-Peak™ Time Delay Fuse, Current Limiting, Series: LP-CC, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 4.5 A, 600 VAC/150 VDC, 20/200 kA Interrupt, Class: CC, 12 s at 200% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 13/32 in Dia x 1-1/2 in L Body Size
QTY
  • 200 kA interrupting rating complies with NEC section 110.9 for today's large capacity systems
  • Fast short circuit protection and dual element, time delay performance provide ultimate protection
  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
  • Consistent 2:1 ampacity ratios for all Low-Peak™ fuses make selective co-ordination easy
  • Time delay characteristic avoids unwanted fuse openings from surge currents while fast response spee
  • Current limitation protects downstream components against damaging thermal and magnetic effects of s
  • A superior, all purpose, space saving branch circuit fuse that meets most protection requirements up
  • Very compact, with a physical size only 13/32 x 1-1/2 in with rejection tip
  • Proper sizing can provide "no damage" type 2 motor starter protection for NEMA® and IEC® motor contr
  • Can be used where either a time delay or a fast acting fuse is needed, making selection easier and r
  • Superior protection for small horsepower motor circuit
  • 12 s minimum at 200% of rated current response time
  • 200 kA at 600 VAC rms symmetrical, 20 kA at 150 VDC interrupt rating
200 kA interrupting rating complies with NEC section 110.9 for today's large capacity systems
Fast short circuit protection and dual element, time delay performance provide ultimate protection
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
Consistent 2:1 ampacity ratios for all Low-Peak™ fuses make selective co-ordination easy
Time delay characteristic avoids unwanted fuse openings from surge currents while fast response speed under short circuit conditions provides a high degree of current limitation
Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
A superior, all purpose, space saving branch circuit fuse that meets most protection requirements up to 30 A
Very compact, with a physical size only 13/32 x 1-1/2 in with rejection tip
Proper sizing can provide "no damage" type 2 motor starter protection for NEMA® and IEC® motor controllers
Can be used where either a time delay or a fast acting fuse is needed, making selection easier and reducing spare fuse inventories for substantial cost reduction
Superior protection for small horsepower motor circuit
12 s minimum at 200% of rated current response time
200 kA at 600 VAC rms symmetrical, 20 kA at 150 VDC interrupt rating