Cooper Crouse Hinds Logo

Box 3/4in Eajt26

130724 MFG #: EAJT26
$117.26 / EA
Estimated Delivery in 3 to 4 Business Days
  • Manufacturer: Eaton
  • Type: Dust-Ignitionproof Explosionproof Raintight, Shape T
  • Series: EAJ
  • Cover Opening Size: 3-3/16
  • Capacity: 20.5, 20-1/2
  • Suitable For Use With: Rigid Conduit, Threaded Rigid Conduit
  • Mounting Type: Pad
  • Material: Feraloy® Iron Alloy
  • Finish: Electro-Galvanized, Electrogalvanized/Aluminum Acrylic Painted
  • Dimensions: 3-3/4 in H x 3-3/4 in W x 2-25/32 in D
  • Brand: Crouse-Hinds
Crouse-Hinds Condulet® Conduit Outlet Box, Dust-Ignitionproof Explosionproof Raintight, Series: EAJ, 3/4 in NPT, 3-3/16 in Cover Opening Size, 20-1/2 cu-in, For Use With: Rigid Conduit, Pad Mount, Feraloy® Iron Alloy, Electro-Galvanized, 3-3/4 in H x 3-3/4 in W x 2-25/32 in D
QTY
  • Class I, Division 1 and 2, Group C, D, Class II, Division 1, Groups E, F, G, Class II, Division 2, G
  • External cover threads on body protecting conductors from damage during pulling
  • Water shedding cover - suitable for wet locations when mounted in upright position
  • No pinching of conductors during cover installation
  • Six different hub arrangements
  • Taper threaded hubs to provide ground continuity
  • Smooth integral hub bushing to protect conductor insulation when pulling
  • Internally threaded cover openings for additional wiring room
  • Flat overlapping threaded covers furnished with boxes
  • Weather-resistant finish
  • Internal green ground screw No 10 standard in all boxes
  • Act as pull and splice boxes
  • Interconnect lengths of conduit
  • Change conduit direction
  • Provide access to conductors for maintenance and future system changes
  • Act as mounting outlets for fixtures
  • Act as sealing fittings
  • Explosion proof dust ignition proof and raintight
  • (3) Side cable entry
  • Electro galvanized and aluminum acrylic painted
  • Class I, Division 1 & 2, Group C, D, Class II, Division 1, Groups E, F, G, Class II, Division 2, Gro
Class I, Division 1 and 2, Group C, D, Class II, Division 1, Groups E, F, G, Class II, Division 2, Groups F, G, Class III, NEMA 3, 4, 7CD, 9EFG
External cover threads on body protecting conductors from damage during pulling
Water shedding cover - suitable for wet locations when mounted in upright position
No pinching of conductors during cover installation
Six different hub arrangements
Taper threaded hubs to provide ground continuity
Smooth integral hub bushing to protect conductor insulation when pulling
Internally threaded cover openings for additional wiring room
Flat overlapping threaded covers furnished with boxes
Weather-resistant finish
Internal green ground screw No 10 standard in all boxes
Act as pull and splice boxes
Interconnect lengths of conduit
Change conduit direction
Provide access to conductors for maintenance and future system changes
Act as mounting outlets for fixtures
Act as sealing fittings
Explosion proof dust ignition proof and raintight
(3) Side cable entry
Electro galvanized and aluminum acrylic painted
Class I, Division 1 & 2, Group C, D, Class II, Division 1, Groups E, F, G, Class II, Division 2, Groups F, G, Class III, NEMA 3, 4, 7CD, 9EFG