3M Canada
3M™ 7000059389 Watertight Fire Barrier Sealant, Pail Container
7000059389
MFG #: 7000059389
$1,477.93
/ EA
Estimated Delivery 7 to 10 Business Days
- Color: Light Gray
- Composition: Calcium Carbonate, Poly(Dimethylsiloxane), Siloxanes and Silcones, Di-Me, Hydroxy Terminated, Ketoxime Silane, Amorphous Silica, (Trimethoxysilylpropyl) Ethylenediamine, Octamethylcyclotetrasiloxane, Quartz silica
- Container Size: 4.5 gal
- Container Type: Pail
- Country of Origin: CA
- Drying Time: 30 to 60 min
- Fire Rating: 3 hr
- Flammability Rating: 1
- Flash Point: >212 deg F
- Form: Paste
- Manufacturer Name: 3M
- Material: Silicon
- Odor/Scent: Low
- Specific Gravity: 1.31 to 1.33
- Temperature Rating: -60 to 300 deg F
- Tensile Strength: 85 psi
- Type: Watertight
- VOC Content: <250 g/L
3M™ fire barrier water-tight sealants 1003 SL are ready-to use, single component, neutral cure, silicone sealants that cure upon exposure to atmospheric humidity to form a flexible firestop seal. 3M™ fire barrier water-tight sealants help control the spread of fire, smoke and noxious gasses before, during and after exposure to a fire when installed in accordance with a listed through penetration or fire-resistive joint assembly.
- Item Features
- Standards
- Application
- Offers compression and extension capability of /-31% for dynamic and static construction joints
- Self-leveling formula is optimal for horizontal applications, eliminating the need for tooling
- Single component sealer is ready-to use with no mixing required
- Neutral cure - delivers higher adhesion with very little odor
- Halogen-free formula helps control spread of noxious gasses, smoke and flame
- Sealant is paintable with primer
- Excellent caulk rate and sealant can be applied with conventional caulking equipment
- Exceptional weatherability for durability during construction
- Formulated as a re-enterable and repairable solution
- Meets UL water leakage Test, W rating (Class 1 requirements)
- Firestop tested up to 3 hr in accordance with ASTM E 814 (UL 1479) and CAN/ULC S115
- Fire resistance tested for construction joint (including curtain wall) systems in accordance with ASTM E 1966 (UL 2079), ASTM E 2307
ASTM E 814 (UL 1479)|CAN/UL C-S115|ASTM E 1966 (UL 2079)|UL Listed|NEC (NFPA 70)|IBC Certified|IFC Certified|IRC Certified|NBCC Certified|NFPA 101|NFPA 5000 Class 1|RoHS Compliant
For used to firestop blank openings, dynamic and static construction joints and the following penetrating items that pass through fire rated floor or wall assemblies